Ask the library
Ask anything about lifting, eating or recovery. The answer comes from the research itself — meta-analyses first — each source cited so you can read it yourself.
Related: Stretch-mediated hypertrophy and loaded stretching
What the studies say
BACKGROUND: Increases in maximal strength and muscle volume represent central aims of training interventions. Recent research suggested that the chronic application of stretch may be effective in inducing hypertrophy. The present systematic review therefore aimed to syntheisize the evidence on changes of strength and muscle volume following chronic static stretching. METHODS: Three data bases were sceened to conduct a systematic review with meta-analysis. …
read the passages
BACKGROUND: Increases in maximal strength and muscle volume represent central aims of training interventions. Recent research suggested that the chronic application of stretch may be effective in inducing hypertrophy. The present systematic review therefore aimed to syntheisize the evidence on changes of strength and muscle volume following chronic static stretching. METHODS: Three data bases were sceened to conduct a systematic review with meta-analysis. Studies using randomized, controlled trials with longitudinal (≥ 2 weeks) design, investigating strength and muscle volume following static stretching in humans, were included. Study quality was rated by two examiners using the PEDro scale. RESULTS: A total of 42 studies with 1318 cumulative participants were identified. Meta-analyses using robust variance estimation showed small stretch-mediated maximal strength increases (d = 0.30 p < 0.001) with stretching duration and intervention time as significant moderators. Including all studies, stretching induced small magnitude, but significant hypertrophy effects (d = 0.20). Longer stretching durations and intervention periods as well as higher training frequencies revealed small (d = 0.26-0.28), but significant effects (p < 0.001-0.005), while lower dosage did not reach the level of significance (p = 0.13-0.39). CONCLUSIONS: While of minor effectiveness, chronic static stretching represents a possible alternative to resistance training when aiming to improve strength and increase muscle size. As a dose-response relationship may exist, higher stretch durations and frequencies as well as long program durations should be further elaborated.
Discussion Nelson et al. [ 60 ], on the one hand, provide support for this assumption as they detected strength increases in the non-stretched contralateral leg. However, on the other hand, Holly et al. [ 114 ] and Barnett et al. [ 115 ] showed no significant increase in EMG activity during stretching in animals. Furthermore, Sola et al. [ 116 ] found stretch-mediated hypertrophy in denervated muscles, indicating a minor role of neural aspects. Therefore, to clarify the role of neural aspects in stretch-mediated adaptations, further research seems necessary. Even though muscle hypertrophy only occurs using higher dosage stretching, our work has significant clinical implications. In general, stretching may represent an alternative to conventional resistance training interventions inducing muscle size- and strength increases. Nevertheless, several aspects must be considered. While Currier et al. [ 117 ] showed moderate to large magnitude maximal strength and muscle size increases of ES = 0.51 and ES = 1.60, respectively, when using resistance training, the present study’s small magnitude effect sizes of ES = 0.28 and ES = 0.45, respectively, showed that even long stretching durations were less effective. Assuming about one hour of stretching on one isolated muscle to achieve meaningful muscle hypertrophy [ 83 ] seems, on the one hand, of limited practical relevance [ 85 ]. On the other hand, passively
Discussion ], additional research is needed to provide more insights into this topic. Further, results indicated that the effects of chronic SS exercises on muscle hypertrophy is moderated by the number of different SS exercises with greater variety of SS exercises generating larger gains in muscle hypertrophy (β = 0.069, [95% CI = 0.041 to 0.097]; p < 0.001). The mean duration of a single stretching exercise constitutes another moderator variable with longer duratio…
read the passages
Discussion ], additional research is needed to provide more insights into this topic. Further, results indicated that the effects of chronic SS exercises on muscle hypertrophy is moderated by the number of different SS exercises with greater variety of SS exercises generating larger gains in muscle hypertrophy (β = 0.069, [95% CI = 0.041 to 0.097]; p < 0.001). The mean duration of a single stretching exercise constitutes another moderator variable with longer durations inducing larger muscle hypertrophy improvements (β = 0.006, [95% CI = 0.002 to 0.010]; p = 0.008). Moreover, the time under stretching per session (β = 0.006, [95% CI = 0.003 to 0.009]; p = 0.001), per week (β = 0.001, [95% CI = 0.000 to 0.001]; p = 0.001) and in total (β = 0.008, [95% CI = 0.003 to 0.013]; p = 0.001) represent additional mediating factors with longer times leading to larger gains in muscle hypertrophy. Arntz et al. [ 9 ] reported that the chronic effects of SS on muscle strength were moderated by the number of repetitions per stretching exercise and session (β = 0.023, p = 0.004 and β = 0.013, p = 0.008, respectively), with more repetitions associated with larger muscle strength improvements. Overall, this leads us to conclude that increasing SS duration appears to be decisive in stimulating hypertrophic
questionable. Furthermore, a greater variety of stretching exercises elicited larger increases in muscle hypertrophy (β = 0.069, [95% CI = 0.041 to 0.097]). Longer durations of single stretching exercises (β = 0.006, [95% CI = 0.002 to 0.010]), time under stretching per session (β = 0.006, [95% CI = 0.003 to 0.009]), per week (β = 0.001, [95% CI = 0.000 to 0.001]) and in total (β = 0.008, [95% CI = 0.003 to 0.013]) induced larger muscle hypertrophy. Regarding joint range of motion, there was a clear positive effect with a moderate point estimate (β = 0.698; 95% PI = 0.147 to 1.249; p < 0.001) and moderate heterogeneity (I2 = 43%). Moreover, findings indicated no significant association between the gains in joint range of motion and the increase in muscle hypertrophy (β = 0.036, [95% CI = - 0.123 to 0.196]; p = 0.638). CONCLUSIONS: This study revealed an overall unclear chronic effect of SS on skeletal muscle hypertrophy, although interpretation across the range of PI suggests a potential modest beneficial effect. Subgroup analysis indicated larger stretching-induced muscle gains in trained individuals, a more varied selection of SS exercises, longer mean duration of single stretching exercise, increased time under SS per session, week, and in total, and possibly in samples with a higher proportion of females. From a practical perspective, it appears that SS exercises may not be highly effective in promoting skeletal muscle hypertrophy unless a higher duration of training is utilized. PROSPERO registration number: CRD42022331762.
Stretch training is widely used in a variety of fitness-related capacities such as increasing joint range of motion, preventing contractures and alleviating injuries. Moreover, some researches indicate that stretch training may induce muscle hypertrophy; however, studies on the topic have been primarily relegated to animal and in vitro models. The purpose of this brief review was to evaluate whether stretch training is a viable strategy to induce muscle hy…
read the passage
Stretch training is widely used in a variety of fitness-related capacities such as increasing joint range of motion, preventing contractures and alleviating injuries. Moreover, some researches indicate that stretch training may induce muscle hypertrophy; however, studies on the topic have been primarily relegated to animal and in vitro models. The purpose of this brief review was to evaluate whether stretch training is a viable strategy to induce muscle hypertrophy in humans. An extensive literature search was performed using PubMed/MEDLINE, SciELO and Scopus databases, using terms related to stretching and muscle hypertrophy. Only human trials that evaluated changes in measures of muscle size or architecture following training protocols that it was performed stretching exercises were selected for inclusion. Of the 10 studies identified, 3 observed some significantly positive effects of stretch training on muscle structure. Intriguingly, in these studies, the stretching was carried out with an apparatus that aided in its performance, or with an external overload. In all studies, the subjects performed stretching at their own self-determined range of motion, and no effect was observed. Of the 5 available studies that integrated stretching into a resistance training programme, 2 applied the stretching in the interset rest period and were the ones that showed enhanced muscle growth. In conclusion, passive, low-intensity stretch does not appear to confer beneficial changes in muscle size and architecture; alternatively, albeit limited evidence suggests that when stretching is done with a certain degree of tensile strain (particularly when loaded, or added between active muscle contractions) may elicit muscle hypertrophy.
The G protein-coupled receptor APJ is a promising therapeutic target for heart failure. Constitutive deletion of APJ in the mouse is protective against the hypertrophy-heart failure transition via elimination of ligand-independent, β-arrestin-dependent stretch transduction. However, the cellular origin of this stretch transduction and the details of its interaction with apelin signaling remain unknown. We generated mice with conditional elimination of APJ …
read the passage
The G protein-coupled receptor APJ is a promising therapeutic target for heart failure. Constitutive deletion of APJ in the mouse is protective against the hypertrophy-heart failure transition via elimination of ligand-independent, β-arrestin-dependent stretch transduction. However, the cellular origin of this stretch transduction and the details of its interaction with apelin signaling remain unknown. We generated mice with conditional elimination of APJ in the endothelium (APJendo-/-) and myocardium (APJmyo-/-). No baseline difference was observed in left ventricular function in APJendo-/-, APJmyo-/-, or control (APJendo+/+, APJmyo+/+) mice. After exposure to transaortic constriction, APJendo-/- mice displayed decreased left ventricular systolic function and increased wall thickness, whereas APJmyo-/- mice were protected. At the cellular level, carbon fiber stretch of freshly isolated single cardiomyocytes demonstrated decreased contractile responses to stretch in APJ-/- cardiomyocytes compared with APJ+/+ cardiomyocytes. Ca2+ transients did not change with stretch in either APJ-/- or APJ+/+ cardiomyocytes. Application of apelin to APJ+/+ cardiomyocytes resulted in decreased Ca2+ transients. Furthermore, hearts of mice treated with apelin exhibited decreased phosphorylation in cardiac troponin I NH2-terminal residues (Ser22 and Ser23) consistent with increased Ca2+ sensitivity. These data establish that APJ stretch transduction is mediated specifically by myocardial APJ, that APJ is necessary for stretch-induced increases in contractility, and that apelin opposes APJ's stretch-mediated hypertrophy signaling by lowering Ca2+ transients while maintaining contractility through myofilament Ca2+ sensitization. These findings underscore apelin's unique potential as a therapeutic agent that can simultaneously support cardiac function and protect against the hypertrophy-heart failure transition. NEW & NOTEWORTHY These data address fundamental gaps in our understanding of apelin-APJ signaling in heart
Recent research showed significant stretch-mediated maximum strength increases when performing stretching between 5 to 120 minutes per day with the calf muscle. However, since the practical applicability of these long stretching durations was questioned and studies exploring the transferability to the upper body are scarce, the aim of this study was to investigate the possibility of using a home-based stretching program to induce significant increases in m…
read the passage
Recent research showed significant stretch-mediated maximum strength increases when performing stretching between 5 to 120 minutes per day with the calf muscle. However, since the practical applicability of these long stretching durations was questioned and studies exploring the transferability to the upper body are scarce, the aim of this study was to investigate the possibility of using a home-based stretching program to induce significant increases in maximum strength and flexibility. Therefore, 31 recreationally active participants (intervention group: 18, control group: 13) stretched the pectoralis major for 15min/day for eight weeks, incorporating three different stretching exercises. The maximum strength was tested isometrically and dynamically in the bench press (one-repetition maximum: 1RM) as well as shoulder range of motion (ROM) performing bilateral shoulder rotation with a scaled bar. Using a two-way analysis of variance (ANOVA) with repeated measures, the results showed high magnitude Time effects (ƞ² = 0.388-0.582, p < 0.001) and Group*Time interaction (ƞ² = 0.281-0.53, p < 0.001-0.002), with increases of 7.4 ± 5.6% in 1RM and of 9.8 ± 5.0% in ROM test in the intervention group. In the isometric testing, there was a high-magnitude Time effect (ƞ² = 0.271, p = 0.003), however, the Group*Time interaction failed to reach significance (p = 0.75). The results are in line with previous results that showed stretch-mediated maximum strength increases in the lower extremity. Future research should address the underlying physiological mechanisms such as muscle hypertrophy, contraction conditions as well as pointing out the relevance of intensity, training frequency and stretching duration.
findings suggest that hamstring aponeurosis dimensions can increase after both eccentric loading and static stretching, whereas muscle hypertrophy is largely eccentric-specific and more sensitive to short-term detraining.
read the passages
findings suggest that hamstring aponeurosis dimensions can increase after both eccentric loading and static stretching, whereas muscle hypertrophy is largely eccentric-specific and more sensitive to short-term detraining.
This study examined the effects of 10 weeks of eccentric knee-flexor training or matched-duration static stretching on hamstring aponeurosis dimensions and muscle size, and explored the changes after 4 weeks of detraining. Eleven healthy untrained men completed a within-participant contralateral intervention (3 sessions·week-1, 10 weeks) followed by 4 weeks of detraining. One leg performed eccentric knee-flexion exercise on an isokinetic dynamometer (3 × 10 reps at 5°·s-1; 50% maximal eccentric torque), while the contralateral leg performed static stretching (3 holds matched to eccentric time under tension). Hamstring outer aponeurosis volumes, inner aponeurosis volumes and widths, and muscle volumes were quantified using magnetic resonance imaging. Outer aponeurosis volume increased after both training protocols across all muscles (p < 0.05) and was maintained during the 4 week detraining period, with comparable changes observed between stretching (~19.0%-31.8%, d = 0.91-1.69) and eccentric training (~15.8%-22.8%, d = 0.85-1.13). Inner-aponeurosis volume and width of biceps femoris long head and semimembranosus also increased after both training protocols (~7%-23%; p < 0.05; d = 0.33-0.86) and were preserved during detraining. Muscle hypertrophy occurred only after eccentric training (~22%-42%; p < 0.05; d = 0.98-1.65) in biarticular hamstrings and remained above baseline in the detraining period. Stretching exercise produced minimal changes in muscle volume (p > 0.05). Changes in muscle volume were not significantly associated with changes in aponeurosis dimensions in almost all cases (p > 0.05). These findings suggest that hamstring aponeurosis dimensions can increase after both eccentric loading and static stretching, whereas muscle hypertrophy is largely eccentric-specific and more sensitive to short-term detraining.
Cardiac hypertrophy is initiated as an adaptive response to sustained overload but progresses pathologically as heart failure ensues. Here we report that genetic loss of APJ, a G-protein-coupled receptor, confers resistance to chronic pressure overload by markedly reducing myocardial hypertrophy and heart failure. In contrast, mice lacking apelin (the endogenous APJ ligand) remain sensitive, suggesting an apelin-independent function of APJ. Freshly isolate…
read the passage
Cardiac hypertrophy is initiated as an adaptive response to sustained overload but progresses pathologically as heart failure ensues. Here we report that genetic loss of APJ, a G-protein-coupled receptor, confers resistance to chronic pressure overload by markedly reducing myocardial hypertrophy and heart failure. In contrast, mice lacking apelin (the endogenous APJ ligand) remain sensitive, suggesting an apelin-independent function of APJ. Freshly isolated APJ-null cardiomyocytes exhibit an attenuated response to stretch, indicating that APJ is a mechanosensor. Activation of APJ by stretch increases cardiomyocyte cell size and induces molecular markers of hypertrophy. Whereas apelin stimulates APJ to activate Gαi and elicits a protective response, stretch signals in an APJ-dependent, G-protein-independent fashion to induce hypertrophy. Stretch-mediated hypertrophy is prevented by knockdown of β-arrestins or by pharmacological doses of apelin acting through Gαi. Taken together, our data indicate that APJ is a bifunctional receptor for both mechanical stretch and the endogenous peptide apelin. By sensing the balance between these stimuli, APJ occupies a pivotal point linking sustained overload to cardiomyocyte hypertrophy.
Stretch-Mediated Hypertrophy: Results from Animal Studies in muscle mass in rat soleus muscle after 3 weeks of immobilization and stretching for 40 min once weekly. In a subsequent study by Coutinho et al. [ 103 ], the authors found that daily stretching for 3 weeks after a prior 4-week immobilization period resulted in a significant increase in rat soleus muscle mass compared with the contralateral control. The methodology used in these studies is therefore not comparable to the procedure used in studies includi…
read the passages
Stretch-Mediated Hypertrophy: Results from Animal Studies in muscle mass in rat soleus muscle after 3 weeks of immobilization and stretching for 40 min once weekly. In a subsequent study by Coutinho et al. [ 103 ], the authors found that daily stretching for 3 weeks after a prior 4-week immobilization period resulted in a significant increase in rat soleus muscle mass compared with the contralateral control. The methodology used in these studies is therefore not comparable to the procedure used in studies including birds, which are listed in Table 1 . Accordingly, lower frequencies and/or stretching durations per session were used, resulting in less hypertrophy, if any. Consequently, the impact of modifying stretching parameters such as duration, frequency, and intensity is more extensively debated in Sect. 5 . Apart from differences in load control, a species-dependent difference in adaptations could also be assumed, raising questions about the transferability of stretch-mediated hypertrophy from birds to humans, particularly given presumed differences in the overall protein synthesis rate [ 49 , 104 , 105 ].
Stretch-Mediated Hypertrophy: Results from Human Studies by Antonio and Gonyea [ 50 , 82 , 114 ]) for up to 56 days. Conversely, Tables 2 and 3 illustrate conflicting results in human studies regarding stretch-induced hypertrophy and strength using stretching devices such as stretching boards or orthoses, while only Simpson et al. [ 44 ] used external weights via a leg press to perform 3 min of stretch per session. While hypertrophy and strength increases can be found with stretching times of as little as 4 × 30 s per day, 3 days per week for 8 weeks [ 115 ], other interventions with similar or longer stretching durations per session and overall intervention periods reported no significant changes [ 38 , 42 , 116 ]. Studies using a comparable load control to animal studies were performed in 2022 and 2023 applying high stretching volumes of 7–14 h per week with daily stretching of 1–2 h [ 40 , 109 , 112 , 113 ] showing more consistent effects regarding hypertrophy and strength increases.
Maximal strength measured via maximal voluntary contraction is known as a key factor in competitive sports performance as well as injury risk reduction and rehabilitation. Maximal strength and hypertrophy are commonly trained by performing resistance training programs. However, literature shows that long-term, long-lasting static stretching interventions can also produce significant improvements in maximal voluntary contraction. The aim of this study is to…
read the passage
Maximal strength measured via maximal voluntary contraction is known as a key factor in competitive sports performance as well as injury risk reduction and rehabilitation. Maximal strength and hypertrophy are commonly trained by performing resistance training programs. However, literature shows that long-term, long-lasting static stretching interventions can also produce significant improvements in maximal voluntary contraction. The aim of this study is to compare increases in maximal voluntary contraction, muscle thickness and flexibility after 6 weeks of stretch training and conventional hypertrophy training. Sixty-nine (69) active participants (f = 30, m = 39; age 27.4 ± 4.4 years, height 175.8 ± 2.1 cm, and weight 79.5 ± 5.9 kg) were divided into three groups: IG1 stretched the plantar flexors continuously for one hour per day, IG2 performed hypertrophy training for the plantar flexors (5 × 10-12 reps, three days per week), while CG did not undergo any intervention. Maximal voluntary contraction, muscle thickness, pennation angle and flexibility were the dependent variables. The results of a series of two-way ANOVAs show significant interaction effects (p < 0.05) for maximal voluntary contraction (ƞ2 = 0.143-0.32, p < 0.006), muscle thickness (ƞ2 = 0.11-0.14, p < 0.021), pennation angle (ƞ2 = 0.002-0.08, p = 0.077-0.625) and flexibility (ƞ2 = 0.089-0.21, p < 0.046) for both the stretch and hypertrophy training group without significant differences (p = 0.37-0.99, d = 0.03-0.4) between both intervention groups. Thus, it can be hypothesized that mechanical tension plays a crucial role in improving maximal voluntary contraction and muscle thickness irrespective whether long-lasting stretching or hypertrophy training is used. Results
Calcium Ca2+ regulation is a key component of numerous cellular functions. In cardiomyocytes, Ca2+ regulates excitation-contraction coupling and influences signaling cascades involved in cell metabolism and cell survival. Prolonged dysregulation of mitochondrial Ca2+ leads to dysfunctional cardiomyocytes, apoptosis and ultimately heart failure. VEGF promotes cardiomyocyte contractility by increasing calcium transients to control the strength of the heartbe…
read the passage
Calcium Ca2+ regulation is a key component of numerous cellular functions. In cardiomyocytes, Ca2+ regulates excitation-contraction coupling and influences signaling cascades involved in cell metabolism and cell survival. Prolonged dysregulation of mitochondrial Ca2+ leads to dysfunctional cardiomyocytes, apoptosis and ultimately heart failure. VEGF promotes cardiomyocyte contractility by increasing calcium transients to control the strength of the heartbeat. Here, we describe a method to measure mitochondrial Ca2+ fluxes in human ventricular cardiomocytes after inducing stretch-mediated hypertrophy in vitro.
high interaction-effect (p=0.015, ƞ²=0.406). In ROM we found in both tests significant increases up to 27.3% with moderate time-effect (p < 0.001, ƞ²=0.129) and high interaction-effect (p < 0.001, ƞ²=0.199). Additionally, we measured significant contralateral force transfers in maximal strength tests of 11.4% (p < 0.001) in 1RM test and 1.4% (p=0.462) in MIS test. Overall, there we no significant effects in control situations for any parameter (CG and non-…
read the passage
high interaction-effect (p=0.015, ƞ²=0.406). In ROM we found in both tests significant increases up to 27.3% with moderate time-effect (p < 0.001, ƞ²=0.129) and high interaction-effect (p < 0.001, ƞ²=0.199). Additionally, we measured significant contralateral force transfers in maximal strength tests of 11.4% (p < 0.001) in 1RM test and 1.4% (p=0.462) in MIS test. Overall, there we no significant effects in control situations for any parameter (CG and non-intervened leg of IG). Discussion: We hypothesize stretching-induced muscle damage comparable to effects of mechanical load of strength training, that led to hypertrophy and thus to an increase in maximal strength. Increases in ROM could be attributed to longitudinal hypertrophy effects, e.g., increase in serial sarcomeres. Measured cross-education effects could be explained by central neural adaptations due to stimulation of the stretched muscles.
Both mechanical and humoral triggers have been put forward to explain the hypertrophic response of the challenged cardiomyocyte. The aim of the present study was to investigate whether cyclic equibiaxial stretch is a direct stimulus for isolated adult rabbit cardiomyocytes to develop hypertrophy and to explore the potential involvement of the autocrine/paracrine factors ANG II, transforming growth factor (TGF)-beta(1), and IGF-I in this process. Isolated c…
read the passage
Both mechanical and humoral triggers have been put forward to explain the hypertrophic response of the challenged cardiomyocyte. The aim of the present study was to investigate whether cyclic equibiaxial stretch is a direct stimulus for isolated adult rabbit cardiomyocytes to develop hypertrophy and to explore the potential involvement of the autocrine/paracrine factors ANG II, transforming growth factor (TGF)-beta(1), and IGF-I in this process. Isolated cardiomyocytes were exposed to 10% cyclic equibiaxial stretch (1 Hz) for up to 48 h or treated with ANG II (100 nM), TGF-beta(1) (5 ng/ml), IGF-I (100 ng/ml), ANG II type 1 (AT(1)) receptor blockers, or conditioned medium of stretched fibroblasts. Cyclic stretch significantly increased cell surface area (+3.1%), protein synthesis (+21%), and brain natriuretic peptide (BNP) mRNA expression (6-fold) in cardiomyocytes. TGF-beta(1) expression increased (+42%) transiently at 4 h, whereas cardiomyocyte IGF-I expression was not detectable under all experimental conditions. The AT(1) receptor blockers candesartan and irbesartan (100 nM) did not prevent the stretch-induced hypertrophic response. Direct exposure to ANG II, TGF-beta(1), or IGF-I did not enhance cardiomyocyte BNP expression. In cardiac fibroblasts, stretch elicited a significant approximately twofold increase in TGF-beta(1) and IGF-I expression. Conditioned medium of stretched fibroblasts increased BNP expression in cardiomyocytes ( approximately 2-fold, P = 0.07). This study clearly indicates that cyclic stretch is a strong, direct trigger to induce hypertrophy in fully differentiated rabbit cardiomyocytes. The present findings do not support the notion that stretch-mediated hypertrophy of adult rabbit cardiomyocytes involves autocrine/paracrine actions of ANG II, TGF-beta(1), or IGF-I.